4-64
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
4
forward
power limit
Limits the forward power in external
power (DC Bias) regulation mode (set
with command
3
) by specifying the
maximum forward power that can be
delivered.
Note:
This command has no effect in
forward power (P
forward
) or load
power (P
real
) regulation mode.
Send two data bytes, least significant
byte first, representing the maximum
forward power in watts.
• Accepts a value of 5% of nominal
power to full nominal power.
Read back with command
169
.
2
1
(CSR only)
5
reflected
power limit
Specifies the maximum reflected power.
Send two data bytes, least significant
byte first, representing the reflected
power limit as a percentage of nominal
power.
• Accepts a value of 1% of nominal
power up to the specified limit.
Read back with command
170
.
2
1
(CSR only)
8
set point
Specifies the output set point level for the
selected regulation mode (set with
command
3
).
Send two data bytes, least significant
byte first, representing the set point level
in watts.
• Accepts a value of 0 to nominal
power (or maximum external
feedback value).
Read back with command
164
.
2
1
(CSR only)
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...