5-10
Installation, Setup, and Operation
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
Changing the IP Configuration
The CESAR generator is designed for use in a BootP environment (that is, a
BootP server is running on the LAN), which will automatically set the unit IP
configuration. However, you can also reset the IP configuration settings in a
non-BootP environment. The following procedures provide instructions for
both situations.
To Change the IP Configuration With BootP:
1. Configure your BootP server to recognize the CESAR generator MAC
address (located on a sticker on the back of the unit, close to the
Ethernet
connector).
2. In the BootP server configuration, set an IP address for the CESAR
generator that is appropriate for your network, and assign the MAC
address of the CESAR generator to this IP address. (Consult your network
administrator to identify appropriate IP address settings.)
3. Connect the CESAR generator to the network (this network should be
routed to the BootP server) using a standard, straight-through network
cable.
4. Power the CESAR generator on. In approximately 30 seconds, the
CESAR generator will be visible to the BootP server and consequently
your network (at the address specified in step 2).
To Change the IP Configuration Without BootP:
If you are using the Modbus CESAR generator in a non-BootP environment,
you need to change the IP configuration through the BootP server utility that
was included (on a CD-ROM) with the unit. For more information on using this
software, see the Online Help system available when you launch the software.
FIRST-TIME OPERATION
Before proceeding with first-time operation, be sure you have satisfied the
installation requirements and completed the installation procedures described
in
“Installation Requirements” on page 5-2
.
There are several ways in which you can operate CESAR generator. Refer to
the section that describes how you intend to operate the generator:
•
“Operating the CESAR Generator for the First Time With the User Port” on
page 5-11
•
“Operating the CESAR Generator for the First Time With Host Port” on
page 5-13
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...