4-16
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
5
18
SET POINT
Analog
input
This signal sets the RF output
set point. Depending on the
regulation mode, the set point
refers to forward power
(P
forward
), load power (P
real
),
or external power (DC Bias).
The default range is 0 V to
10 V, but you can change this
range (see
A 0 V to 10 V signal applied to
this pin linearly controls the
set point of the CESAR
generator:
Default setting: 0 V to 10 V =
0 W to 1.2 kW
For DC bias regulation, the
scaling of the set point must
be the same as for the DC
bias signal (see pin 7).
For a wiring diagram, see
.
6
19
RF FORWARD
POWER/
DC BIAS
REGULATION
Digital
input
Use this signal to select DC
bias or RF power regulation
mode. To regulate on DC bias
input, apply a positive voltage
of 4 V to 30 V to this pin. To
regulate on forward or load
power, apply a voltage of 1.5
V or less or an open
connection.
See pin 8 for switching
between forward and load
power regulation.
For a wiring diagram, see
.
Table 4-2. 25-pin User Port pin descriptions (Continued)
Pin
Number
Return
Pin
Name
Signal
Type
Description
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...