CESAR 1312 (E)
Communication Interfaces
4-45
CESAR™ 1312 Generator
4
57600
4
115200
•
Odd parity
•
One start bit, eight data bits, one stop bit
•
Low-order bytes are transmitted before high-order bytes.
The host computer must finish one transaction with the CESAR generator
before it initiates another one, either with the same unit or any other unit.
Note:
The CESAR generator sends data through pin 2 (
TXD.D
). This pin must
be connected to the receive pin (
RXD.D
) on the host computer’s serial
connector. The receive pin is normally pin 2 for a standard, 9-pin serial
port and normally pin 3 for a standard, 25-pin serial port.
AE BUS PROTOCOL
The AE Bus protocol uses pure binary data (nothing is coded in ASCII) and is
designed to facilitate direct communications between a host computer and the
CESAR generator.
The AE Bus message packet combines a set quantity of bits and bytes in such
a way that groups of information can be sent over communications lines at
one time. Five types of information (fields) make up communications message
packets (see
):
•
Header (address and the length of Data field)
•
Command Number (commands are listed in
•
Optional Length byte
•
Data
•
Checksum
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...