5-8
Installation, Setup, and Operation
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
Connecting AC Input (Mains) Power
The AC input (
Mains
) connector is an IEC 320 connector.
shows
the input power connector, and describes each pin.
Figure 5-3. Input (Mains) connector
To Connect the AC Input Power:
Connect the CESAR generator to the power mains by connecting the AC
mains cord with 230 VAC (187 VAC to 253 VAC), 1
φ
.
Note:
The
ON/OFF
power switch does not completely disconnect the
Mains
.
You must install an external switch to completely disconnect
Mains
.
Before making any input line power connection, turn off and lockout/
tagout all circuit breakers supplying input power to the CESAR
generator.
Never connect the generator to the mains while the cabinet is open.
Table 5-2. Input connector pin description
Pin
Description
1
Phase (or neutral if pin 2 is
phase)
2
Neutral (or phase if pin 1 is
neutral)
3
Ground
1
2
3
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...