CESAR 1312 (E)
Communication Interfaces
4-73
CESAR™ 1312 Generator
30
set User
Port scaling
Sets
User
Port
(analog) voltage scaling
from 0 V to a range of 2 V to 10 V in
steps of 0.5 V.
Send one data byte.
• A factor of 2 is applied (for example,
5 = 2.5 V).
Read back with command
158
.
1
1
(CSR only)
31
set RF-on
ramping
rise time
Sets RF-on ramping rise time.
Send two data bytes, least significant
byte first, representing the RF-on
ramping rise time in tenths of a second.
Read back with command
151
.
2
1
(CSR only)
32
set RF-on
ramping fall
time
Sets RF-on ramping fall time.
Send two data bytes, least significant
byte first, representing the RF-on
ramping fall time in tenths of a second.
Read back with command
151
.
2
1
(CSR only)
33
set
reflected
power
parameters
Sets reflected power parameters.
Send three data bytes, least significant
byte first.
• Byte 1 sets the number of seconds
(after reaching the limit set by bytes
2 and 3) until RF is turned off.
4
Accepts a value of 1 s to 255 s
4
0 = Off
• Bytes 2 and 3 set the reflected power
limit that triggers the timer set by byte
1.
Note:
If the time is set to 0, this function is
disabled.
For more information, see
Reflected Power Settings” on page 5-48
.
Read back with command
152
.
3
1
(CSR only)
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...