4-80
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
162
report
process
status
Reports process status. The controller
returns the following packet arranged as
follows.
1st status byte (bit flags):
• 0 = Reserved
• 1 = Unassigned
• 2 = Recipe run is active
• 3 = Reserved
• 4 = Reserved
• 5 = Output power (0 = Off, 1 = On)
• 6 = RF on requested (0 = Off, 1 = On)
• 7 = Set point status (0 = Within
tolerance, 1 = Out of tolerance)
2nd status byte (bit flags):
• 0 = End of target life
• 1 = Reserved
• 2 = Reserved
• 3 = Overtemperature
• 4 = Reserved
• 5 = Reserved
• 6 = Unassigned
• 7 = Interlock open
3rd status byte (bit flags):
• 0 = Reserved
• 1 = Reserved
• 2 = Reserved
• 3 = Unassigned
• 4 = Reserved
• 5 = Out of set point
• 6 = Reserved
• 7 = Reserved
(continued on next page)
0
4
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...