CESAR™ 1312 Generator
To Select Forward Power Regulation Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
CESAR generator:
1. Select forward power regulation mode:
Send one data byte for command
3
(see
).
4
6 = Forward power regulation
2. Specify the output set point level for the regulation mode:
Send two data bytes, least significant byte first, for command
8
representing the set point level in watts (see
To Select Forward Power Regulation Using the CESAR Generator Front Panel:
Complete the following steps to select P
forward
regulation using the front panel:
1. Press the
Program
soft key.
Control Settings
appears on the display.
2. Press
Change
.
3. Press
Control P
forward
.
4. Select the desired power set point between 0 W and 1.2 kW using the
RF
POWER
dial knob. Press the
Increm Auto
soft key to toggle between
dynamic increments (Auto) and several fixed increments.
5. Press
Ok
to confirm.
6. Press
Exit
.
7. Press
Execute
.
The operating screen will then display the forward power in watts, the reflected
power in watts, and the
Program
and
Display
soft keys.
SETTING LOAD POWER REGULATION MODE (P
REAL
)
In load power regulation mode, the CESAR Generator regulates RF power
with constant load (real) power. This section explains how to select load power
regulation using the
User Port
, the
Host
port, or the front panel.
To Select Load Power Regulation Through the User Port:
If you are using the 25-pin
User Port
, see pin 8,
If you are using the 15-pin
User Port
, see pin 2,
and
.
To Select Load Power Regulation through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
CESAR generator:
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...