CESAR 1312 (E)
Installation, Setup, and Operation
5-41
CESAR™ 1312 Generator
The analog interface level is factory set to the most common level range
of 0 V to 10 V. However, you may reprogram this value by changing the
maximum voltage of possible analog interface levels from 2 V to 10 V.
These levels apply to all analog inputs and outputs on the user port.
•
DC Bias Scaling
You may set the maximum DC bias in volts from 0 V to 4000 V (in
increments of 1, 10, 100, 10000, and Auto). 4000 V is the default value.
•
Control by
This feature lets you choose between
Front Panel
control and
User Port
control in which the generator will try to detect the
User Port
.
•
RS232 baud rate
If your CESAR generator has an RS-232 port, this function allows you to
select the desired baud rate: 9600, 19200, 38400, 56000, or 115200.
Note:
To determine if you have an RS-232 port, see
Model 1312 Options” on page 1-2
•
RS232 protocol
If your CESAR generator has an RS232 port, the RS-232 protocol is
factory-set to
AE Bus
, and most CESAR generators will use the default
AE Bus protocol (see
“AE Bus Protocol” on page 4-45
). However, a
previous protocol (
Dressler
) is available for compatibility.
Note:
To determine if you have an RS-232 port, see
Model 1312 Options” on page 1-2
To Change the Default Device Configuration Settings Using the CESAR
Generator Front Panel:
1. Press the
Program
soft key.
2. Press
Next
until you see
Device Configuration
on the display.
3. Press
Change
.
4. Select the desired
Displ. Contrast
value using the
RF POWER
rotary dial
knob.
5. Press
Ok
to confirm.
6. Press the desired
Analog I/O Max
level using the
RF POWER
rotary dial
knob.
4
You may select values between 2 V and 10 V.
7. Press
Ok
to confirm.
8. Select the desired
DC Bias Scaling
using the
RF POWER
rotary dial
knob.
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...