4-78
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
152
report
reflected
power
parameters
Reports reflected power parameters.
The controller returns three data bytes,
least significant byte first:
• Byte 1 reports the time until RF is
turned off in seconds
• Bytes 2 and 3 report the reflected
power detection level in watts.
Note:
If the time is set to 0, this function is
disabled.
Set with command
33
.
0
3
154
report
regulation
mode
Reports regulation mode.
The controller returns one data byte
representing the regulation mode:
• 6 = Forward power (P
forward
)
regulation
• 7 = Load power (P
real
) regulation
• 8 = External power (DC Bias)
regulation
Set with command
3
.
0
1
155
report
control
mode
Reports the control mode.
The controller returns one data byte
representing the control mode:
• 2 = Host
• 4 = User Port
• 6 = Local (Front Panel)
Set with command
14
.
0
1
156
report
active
target
Reports the number of the active target.
Set with command
11
.
0
1
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...