To Set a Target Lifetime Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
CESAR generator:
1. Specify the number of targets:
Send one byte for command 11 (see
2. Set the target life with command 12 (see
a. Send one byte to select the target number (1 to 4).
b. Send the remaining bytes 2 through 5 to specify the target life in kilowatt
hours.
Note:
A decimal is implied (for example, 100 = 1 kWh).
To Set a Target Lifetime Using the CESAR Generator Front Panel, see
instructions on
Changing Reflected Power Settings
Normally, a generator delivers continuous reflected power; however, the
CESAR generator allows you to set a value at which the forward power will
fold back when the reflected power reaches a certain limit for a specified
period of time. The
Reflected Power Settings
menu allows you to create a
“reaction profile” to shut off RF power when the reflected power reaches this
limit.
To Set a Reflected Power Reaction Profile Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
CESAR generator, set the reflected power parameter using command
33
(see
).
1. Send one byte to set the time until RF is turned off in seconds.
2. Send the remaining bytes 2 and 3 to set the reflected power detection level
in watts.
To Set a Reflected Power Reaction Profile Using the CESAR Generator Front
Panel, see instructions on
.
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...