6-12
Troubleshooting and Customer Support
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
WORLD WIDE WEB SITE
For additional product information and troubleshooting procedures, consult
Dressler
®
HF-Technik GmbH’s World Wide Web site:
W30
RF will switch OFF
in X s
The CESAR generator allows you to interrupt power if the
reflected power exceeds a specified threshold for a
specified period of time. This message occurs when the
actual reflected power is above the threshold for power
interruption. RF will switch off after the specified period of
time. To avoid this situation, check your load or change
the reflected power settings (see
).
W40
Ext. pulse at limit!
The external pulse frequency has exceeded the
maximum. The generator has turned off to protect itself
from damage.
Causes: Either the pulse repetition frequency is too high
or the duty cycle is too low for the actual pulse repetition
frequency.
Solution: Change the external pulse frequency to be
within limits. See
“Electrical Specifications” on page 3-4
for pulse frequency limits. You can change the pulse
frequency the
Host
port command 93 (see
) or through the front panel (see
).
W41
Frequency at limit!
In frequency shift tuning (FST), the output frequency has
reached its upper or lower limit.
Therefore, the phase
controller is not working at set point.
Cause: VSWR is too high.
Solution: Reduce VSWR.
W50
Target lifetime has
expired
The target lifetime counter has reached the user-set
target life limit. This warning does not affect the operation
of the unit.
Solution: Change target or reset target lifetime counter.
You can make these settings through the
Host
port
commands 11 and 12 (see
) or
through the front panel (see
Table 6-2. Warning description and resolution (Continued)
Warning Message
Description and Resolution
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...