CESAR 1312 (E)
Communication Interfaces
4-63
CESAR™ 1312 Generator
•
Command numbers
128
through
255
request information from the unit,
such as output on/off status and unit settings. The unit responds to these
commands by sending the data requested.
For AE bus, unless otherwise specified for individual commands, any value
greater than one byte must be sent and received least significant byte (LSB)
first. For example, if a command contained 7 data bytes made up of one 8-bit
value, one 16-bit value, and one 32-bit value, the 7 data bytes would be sent
in the following order:
0, 2, 1, 6, 5, 4, 3 (0 = 8-bit value, 2 and 1 = 16-bit value, 6 through 3 = 32-bit
value).
Most host port commands are the same for all of the available interfaces.
Differences are noted where they exist.
describes the CESAR
generator host port commands.
Table 4-16. Host port commands
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
1
RF off
Turns off RF output.
Read back with command
162
.
0
1
(CSR only)
2
RF on
Turns on RF output
Read back with command
162
.
0
1
(CSR only)
3
regulation
mode
Sets the regulation mode.
Send one data byte, indicating the
desired regulation mode:
• 6 = Forward power (P
forward
)
regulation
• 7 = Load power (P
real
) regulation
• 8 = External power (DC Bias)
regulation
Note:
You cannot change regulation
mode while RF power is on.
For a description of regulation modes,
see
.
Read back with command
154
.
1
1
(CSR only)
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...