CESAR 1312 (E)
Communication Interfaces
4-83
CESAR™ 1312 Generator
169
report
forward
power limit
Reports programmed limit for forward
power.
The controller returns the user forward
power limit in watts.
Set with command
4
.
0
2
170
report
reflected
power limit
Reports reflected power limit.
The controller returns two data bytes
representing the value in watts.
Set with command
5
.
0
2
175
report
capacitor
positions
Reports current load and series motor
positions.
The controller returns four data bytes,
least significant byte first.
• Bytes 1 and 2 report the current load
position (0 to 1000)
• Bytes 3 and 4 report the current
series position (0 to 1000).
Set with commands
112
and
122
or by
using the automatic tune process.
0
4
177
report
pulsing
Reports pulsing settings. The controller
returns one data byte.
• 0 = Pulsing off
• 1 = Internal pulsing
• 2 = External pulsing
• 3 = External pulsing inverted
• 4 = Enable internal pulsing by
external pulsing input
Set with command
27
.
0
1
178
report RF
frequency
Reports RF frequency in Hertz.
Note:
This command is only available on
generators with variable frequency.
Set with command
18
.
0
4
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...