CESAR 1312 (E)
Communication Interfaces
4-59
CESAR™ 1312 Generator
6
Unit ID
0 (denotes the default AE Bus address)
7
Function code
23 = 0x17h
8 and 9
Reference
number for
read
0xFFFFh
Note:
This value is necessary to denote
the special use of FC23 (mapping
to AE Bus commands).
10 and 11
Word count
Not used
12 and 13
Reference
number for
write
0xFFFFh
Note:
This value is necessary to denote
the special use of FC23 (mapping
to AE Bus commands).
14 and 15
Word count for
write
Not used
16
Byte count for
write
Not used
17
AE Bus
command
number
AE Bus command number; see
complete list of commands
18
Number of
bytes in AE
Bus write
packet
Total number of bytes in the AE Bus
packet; for a description of the AE Bus
packet, see
; for information on the number
of data bytes in
each AE Bus command,
see
19 and up
AE Bus data
bytes
Data bytes contained in the AE Bus
packet; for a description of the data bytes
for each command, see
Note:
Modbus word swapping does not
affect the order of these bytes.
These bytes should be ordered as
necessary for the AE Bus
command (least significant bytes
first).
Table 4-12. Packet format for FC23 send (Continued)
Byte
Numbers
Purpose
Value to Send
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...