CESAR 1312 (E)
Communication Interfaces
4-71
CESAR™ 1312 Generator
23
recipe step/
run time
Sets the run time in seconds for a
specified recipe step.
Send three data bytes, least significant
byte first.
• Byte 1 selects the recipe step
number (1 to 2) (set with command
19
).
• Bytes 2 and 3 set the run time in
seconds
For more information, see
Read back with command
188
.
3
1
(CSR only)
24
save
presets
Saves the current operation parameters
to EEPROM as a preset with the given
number (0 to 5).
1
1
(CSR only)
25
restore
presets
Restores the current operation
parameters to EEPROM as preset with
the given number (0 to 5).
1
1
(CSR only)
27
set pulsing
Sets the desired pulsing. Send one data
byte.
• 0 = Pulsing off
• 1 = Internal pulsing
• 2 = External pulsing
• 3 = External pulsing inverted
• 4 = Enable internal pulsing by
external pulsing input
See also commands
93
and
96
.
For more information, see
Pulsing Function” on page 5-44
.
Read back with command
177
.
1
1
(CSR only)
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...