Warning Descriptions and Resolutions
Warning conditions do not shut output power off, and the warning message is
cleared when the condition that caused the warning condition is gone. The
front panel only displays one warning message at a time. Overload warnings
indicate that an operating limit has been exceeded, and the unit has reduced
output power to remain within the allowable range.
When an overload warning
is active, the unit is not meeting set point.
On the front panel, overload
messages end with an exclamation point.
E97 Invalid EEPROM
Contents
Controller fault: Parameter data is corrupt.
Cause: Checksum error or invalid data
Solution: Switch generator off and on again.
If this error persists, contact Customer Support (see
“Customer Support” on page 6-14
).
E98 Invalid Calibration
Data
Controller fault: Calibration data is corrupt.
Cause: Checksum error or invalid data
Solution: Switch generator off and on again.
If this error persists, contact Customer Support (see
“Customer Support” on page 6-14
).
Table 6-1. Error description and resolution (Continued)
Error Message
Description and Resolution
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...