CESAR 1312 (E)
Communication Interfaces
4-35
CESAR™ 1312 Generator
14
8
TEST
VOLTAGE
FOR
REFLECTED
POWER
Analog
output
This signal provides a linearly
scaled setting to reflected power as
measured at the generator output.
The default range is 0 V to 10 V,
but you can change this range (see
)
For example, 5 V = 50% of the
nominal generator power; 10 V =
100%.
For a wiring diagram, see
15
8
TEST
VOLTAGE
FOR DC SELF
BIAS
Analog
output
This signal provides a linearly
scaled setting to DC self bias
voltage as measured at the
matching network. The default
range is 0 V to 10 V, but you can
change this range (see
For example, 5 V = 50% of the
nominal DC bias (4 kV); 10 V =
100%.
For a wiring diagram, see
Table 4-4. 15-pin User Port pin descriptions (Continued)
Pin
Number
Return
Pin
Name
Signal
Type
Description
Table 4-5. Setting regulation mode with 15-pin User Port pins 1 and 2
Operating
Mode A
(Pin 1)
Operating
Mode B
(Pin 2)
Control
Setting
Description
Low
Low
Local
No remote control function
Low
High
Remote
RF forward power (P
forward
)
High
Low
Remote
External power (DC Bias
High
High
Remote
Load power (P
real
)
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...