Chapter 12 Troubleshooting
11
11.3.17
MC_ReadStatus
FB/FC
Explanation
Applicable model
FB
MC_ReadStatus is used to read the servo axis state in the controller.
DVP15MC11T
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
Axis
Specify the number of the
axis which is to be
controlled
USINT
1~32
(The variable
value must be set)
When Enable
changes to TRUE
Enable
The instruction is
executed when
Enable
changes to TRUE.
BOOL
TRUE or FALSE
(FALSE)
-
Output Parameters
Parameter name
Function
Data type
Valid range
Valid
TRUE when the output of the instruction is valid.
BOOL
TRUE / FALSE
Busy
TRUE while the instruction is being executed.
BOOL
TRUE / FALSE
Error
TRUE while there is an error in the execution of the
instruction.
BOOL
TRUE / FALSE
ErrorID
Contains error codes when an error occurs. Please
refer to section 12.2 for the corresponding error code.
WORD
ErrorStop
Refer to section 10.4.
BOOL
TRUE / FALSE
Disabled
BOOL
TRUE / FALSE
Stopping
BOOL
TRUE / FALSE
Homing
BOOL
TRUE / FALSE
Standstill
BOOL
TRUE / FALSE
DiscreteMotion
BOOL
TRUE / FALSE
ContinuousMotion
BOOL
TRUE / FALSE
SyncMotion
BOOL
TRUE / FALSE
Notes:
1. When
Enable
changes from FALSE to TRUE, the execution of MC_ReadStatus starts and the axis
status is read.
MC_ReadSt atus
Ax is
Valid
MC_ReadS tatus _inst anc e
En able
Busy
E rro r
ErrorID
ErrorSt op
Disabled
Homing
S tands till
Dis c re teMotion
Continuous Motion
S topping
Sync Motion
11-101
Содержание DVP15MC11T
Страница 9: ...Memo viii...
Страница 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Страница 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Страница 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Страница 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Страница 213: ...DVP15MC11T Operation Manual _8 The program 1 LIMIT EN ENO MN Out MX In LIMIT_EN LIMIT_MN LIMIT_MX LIMIT_In Out1 8 142...
Страница 216: ...Chapter 8 Logic Instructions 8_ The program 1 BAND EN ENO MN Out MX In BAND_EN BAND_MN BAND_MX BAND_In Out1 8 145...
Страница 249: ...DVP15MC11T Operation Manual _8 8 178...
Страница 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Страница 286: ...9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2 9 1...
Страница 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Страница 549: ...DVP15MC11T Operation Manual A MEMO A 16...
Страница 571: ...DVP15MC11T Operation Manual C Memo C 10...
Страница 572: ...D Appendix D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2 D 1...