Chapter 12 Troubleshooting
11
11.3.13
MC_Reset
FB/FC
Explanation
Applicable model
FB
MC_Reset clears the error states and axis alarm information inside
DVP15MC11T.
DVP15MC11T
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
Axis
Specify the number of
the axis which is to be
controlled.
USINT
1~32
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Execute
The instruction is
executed when
Execute
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(FALSE)
-
Output Parameters
Parameter
name
Function
Data type
Valid range
Done
TRUE when the instruction execution is completed.
BOOL
TRUE / FALSE
Busy
TRUE when the instruction is being executed.
BOOL
TRUE / FALSE
Error
TRUE when an error occurs in execution of the
instruction.
BOOL
TRUE / FALSE
ErrorID
Contains the error code when an error occurs. Please
refer to section 12.2 for the corresponding error ID.
WORD
Output Update Timing
Parameter
Name
Timing for changing to TRUE
Timing for changing to FALSE
Done
When the instruction execution is
completed.
When
Execute
changes from TRUE to
FALSE after the instruction execution is
completed.
Done
changes to TRUE when the
instruction execution is completed after
Execute
changes from TRUE to FALSE
during the instruction execution. One cycle
later,
Done
changes to FALSE.
Busy
When
Execute
is TRUE.
When
Done
changes to TRUE.
When
Error
changes to TRUE.
Error
When the input parameter values of the
instruction are illegal or the mistake
cannot be cleared.
When
Execute
changes from TRUE to
FALSE
MC_Reset
Ax is
Done
MC_Reset_inst ance
Ex ecut e
Busy
Erro r
ErrorID
11-87
Содержание DVP15MC11T
Страница 9: ...Memo viii...
Страница 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Страница 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Страница 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Страница 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Страница 213: ...DVP15MC11T Operation Manual _8 The program 1 LIMIT EN ENO MN Out MX In LIMIT_EN LIMIT_MN LIMIT_MX LIMIT_In Out1 8 142...
Страница 216: ...Chapter 8 Logic Instructions 8_ The program 1 BAND EN ENO MN Out MX In BAND_EN BAND_MN BAND_MX BAND_In Out1 8 145...
Страница 249: ...DVP15MC11T Operation Manual _8 8 178...
Страница 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Страница 286: ...9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2 9 1...
Страница 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Страница 549: ...DVP15MC11T Operation Manual A MEMO A 16...
Страница 571: ...DVP15MC11T Operation Manual C Memo C 10...
Страница 572: ...D Appendix D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2 D 1...