DVP15MC11T Operation Manual
11
1
11.3.8
MC_MoveAbsolute
FB/FC
Explanation
FB/FC
FB
MC_MoveAbsolute is used to make the axis move to the specified
absolute target position at the given speed, acceleration and deceleration.
DVP15MC11T
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation
timing
Axis
Specify the number of the
axis which is to be
controlled
USINT
1~32
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Execute
The instruction is
executed when
Execute
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(FALSE)
-
ContinuousUpdate
Reserved
-
-
-
Position
Specify the absolute
target position.
Rotary axis: 0
≤
Position<
Modulo
Linear axis: No limit to
Position.
(Unit: Unit)
LREAL
Negative number,
positive number or 0
(
0
)
When
Execute
changes from
FALSE to TRUE
Velocity
Specify the target velocity.
(Unit: Unit/s)
LREAL
Positive number
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Acceleration
Specify the target
acceleration.
(Unit: Unit/s
2
)
LREAL
Positive number
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Deceleration
Specify the target
deceleration.
(Unit: Unit/s
2
)
LREAL
Positive number
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Jerk
Specify the change rate of
target acceleration or
deceleration.
(Unit: Unit/s
3
)
LREAL
Positive number
(The variable value
must be set)
When
Execute
changes from
FALSE to TRUE
Direction
Specify the rotation
direction (which is valid
only when the axis is the
rotary axis).
MC_Direction
1: mcPositive-
Direction,
2: mcShortestWay,
When
Execute
changes from
FALSE to TRUE
and the axis is in
MC_Mov eAbsolute
Ax is
Done
MC_MoveAbs olut e_ins tanc e
Ex ecut e
Cont inuous Upda te
Busy
Ac tiv e
Pos ition
Error
ErrorID
CommandAborted
Ac celeration
Deceleration
Jerk
Direc tion
Veloc it y
Buf ferMode
11-52
Содержание DVP15MC11T
Страница 9: ...Memo viii...
Страница 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Страница 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Страница 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Страница 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Страница 213: ...DVP15MC11T Operation Manual _8 The program 1 LIMIT EN ENO MN Out MX In LIMIT_EN LIMIT_MN LIMIT_MX LIMIT_In Out1 8 142...
Страница 216: ...Chapter 8 Logic Instructions 8_ The program 1 BAND EN ENO MN Out MX In BAND_EN BAND_MN BAND_MX BAND_In Out1 8 145...
Страница 249: ...DVP15MC11T Operation Manual _8 8 178...
Страница 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Страница 286: ...9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2 9 1...
Страница 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Страница 549: ...DVP15MC11T Operation Manual A MEMO A 16...
Страница 571: ...DVP15MC11T Operation Manual C Memo C 10...
Страница 572: ...D Appendix D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2 D 1...