3–Adapter Management Applications
Windows Management Applications
CU0354602-00 A
3-53
For every test performed, the diagnostic utility shows the following data:
Total number of attempts
Number of successful completions
Number of failures
You can either perform all tests in succession, or perform only specific tests
specified by the preceding command-line parameters.
You can run additional diagnostics in the CLI as listed in the following table. To
determine the
cna_port_inst
, issue the
qaucli -nic –i
command as
shown in
Table 3-8
.
-L
---IntLB
Internal loopback test (default)
-H
--Hw
Hardware test (default)
-S
--LinkST
Link status test (default)
-nR
--noCRegs
No control registers test (combine –D or –a)
-nl
--noIRQS
No interrupt test (combine –D or –a)
-nL
--noIntLP
No internal loopback test (combine –D or –a)
-nH
--noHw
No hardware test (combine –D or –a)
-nS
--noLinkSt
No link status test (combine –D or –a)
-h
--help
View help text
Table 3-7. Windows QConvergeConsole CLI—Diagnostic Test
Commands (Continued)
Command
Description
Содержание Qlogic QME8242
Страница 162: ...4 Boot Configuration DHCP Boot Setup iSCSI 4 36 CU0354602 00 A ...
Страница 164: ...A Troubleshooting NIC Troubleshooting A 2 CU0354602 00 A NIC Troubleshooting Figure A 1 NIC Diagnostics Flowchart ...
Страница 165: ...A Troubleshooting iSCSI Troubleshooting CU0354602 00 A A 3 iSCSI Troubleshooting Figure A 2 iSCSI Diagnostics Flowchart ...
Страница 166: ...A Troubleshooting FCoE Troubleshooting A 4 CU0354602 00 A FCoE Troubleshooting Figure A 3 FCoE Diagnostics Flowchart ...
Страница 168: ...A Troubleshooting ESX Troubleshooting A 6 CU0354602 00 A ...
Страница 172: ...B Specifications Environmental Specifications B 4 CU0354602 00 A Notes ...
Страница 177: ......