2-411
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference
OL-13271-03
Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commands
radius-server dead-criteria
radius-server dead-criteria
Use the
radius-server dead-criteria
global configuration command on the switch stack or on a
standalone switch to configure the conditions that determine when a RADIUS server is considered
unavailable or
dead
. Use the
no
form of this command to return to the default settings.
radius-server dead-criteria
[
time
seconds
[
tries
number
] |
tries
number
]
no radius-server dead-criteria
[
time
seconds
[
tries
number
] |
tries
number
]
Syntax Description
Defaults
The switch dynamically determines the
seconds
value that is from 10 to 60 seconds.
The switch dynamically determines the
tries
value that is from 10 to 100.
Command Modes
Global configuration
Command History
Usage Guidelines
We recommend that you configure the
seconds
and
number
parameters as follows:
•
Use the
radius-server timeout
seconds
global configuration command to specify the time in
seconds during which the switch waits for a RADIUS server to respond before the IEEE 802.1x
authentication times out. The switch dynamically determines the default
seconds
value that is from
10 to 60 seconds.
•
Use the
radius-server retransmit
retries
global configuration command to specify the number of
times the switch tries to reach the RADIUS servers before considering the servers to be unavailable.
The switch dynamically determines the default
tries
value that is from 10 to 100.
•
The
seconds
parameter is less than or equal to the number of retransmission attempts times the time
in seconds before the IEEE 802.1x authentication times out.
•
The
tries
parameter should be the same as the number of retransmission attempts.
Examples
This example shows how to configure 60 as the
time
and 10 as the number of
tries
, the conditions that
determine when a RADIUS server is considered unavailable
Switch(config)#
radius-server dead-criteria time 60 tries 10
You can verify your settings by entering the
show running-config
privileged EXEC command.
time
seconds
(Optional) Set the time in seconds during which the switch does not need to get a valid
response from the RADIUS server. The range is from 1 to 120 seconds.
tries
number
(Optional) Set the number of times that the switch does not get a valid response from
the RADIUS server before the server is considered unavailable. The range is from 1 to
100.
Release
Modification
12.2(40)EX1
This command was introduced.