2-111
Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference
OL-13271-03
Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commands
diagnostic monitor
diagnostic monitor
Use the
diagnostic monitor
global configuration command to configure health-monitoring diagnostic
testing. Use the
no
form of this command to disable testing and to return to the default settings.
diagnostic monitor interval switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
hh:mm:ss
milliseconds
day
diagnostic monitor switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
diagnostic monitor syslog
diagnostic monitor threshold switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
failure
count
count
no diagnostic monitor
interval switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
no diagnostic monitor
switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
no diagnostic monitor
syslog
no diagnostic monitor threshold switch
number
test
{
name
|
test-id
|
test-id-range
|
all
}
failure
count
count
Syntax Description
interval
Configure the interval between tests.
switch
number
Specify the switch number, which is the stack member number. If the
switch is a standalone switch, the switch number is 1. If the switch is in a
stack, the range is 1 to 9, depending on the switch member numbers in the
stack.
This keyword is supported only on stacking-capable switches.
test
Specify the tests to be run.
name
Specify the name of the test. For more information, see the “Usage
Guidelines” section.
test-id
Specify the ID number of the test. The range is from 1 to 7. For more
information, see the “Usage Guidelines” section.
test-id-range
Specify more than one test with the range of test ID numbers. For more
information, see the “Usage Guidelines” section.
all
Specify all of the diagnostic tests.
hh:mm:ss
Configure the monitoring interval in hours, minutes, and seconds. For
formatting information, see the “Usage Guidelines” section.
milliseconds
Configure the monitoring interval in milliseconds (ms). The range is from
0 to 999 ms.
day
Configure the monitoring interval in the number of days. The range is from
0 to 20 days. For formatting information, see the “Usage Guidelines”
section.
syslog
Enable the generation of a syslog message when a health-monitoring test
fails.