![Daikin VRVII Скачать руководство пользователя страница 222](http://html1.mh-extra.com/html/daikin/vrvii/vrvii_manual_4705257222.webp)
Troubleshooting by Indication on the Remote Controller
217
Troubleshooting
Output current check
YES
NO
NO
Compressor
overload
Inspection of the
compressor and
refrigerant
system is
required.
The
secondary
current of the
inverter is higher
than 16.5A (Y1, YL
power supply) and
25.1 A (TL power
supply) for
each
phase.
YES
Replace the
compressor.
Compressor
inspection. The
compressor's coil is
disconnected.
Disconnect the connection
between the compressor
and inverter. Make the
power transistor check
mode setting ON by
service mode.
Caution
Be sure to turn off the power switch before
connecting or disconnecting connectors, or parts
may be damaged.
A
Содержание VRVII
Страница 1: ...Pocket Manual Service Diagnosis Si30 701_A...