18-30
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 18 DLPs D100 to D199
DLP- D136 Provision CE-100T-8 Ethernet Ports
•
If the SFP (PPM) is physically present when you delete the PPM provisioning, CTC transitions to
the deleted state; the ports (if any) are deleted, and the PPM is represented as a gray graphic in CTC.
The SFP can be provisioned again in CTC or the equipment can be removed, in which case the
removal causes the graphic to disappear.
Step 6
If you need to remove the SFP, see the
“DLP-D336 Remove GBIC or SFP/XFP Device” task on
.
Step 7
Return to your originating procedure (NTP).
DLP-D136 Provision CE-100T-8 Ethernet Ports
Note
You can provision SONET contiguous concatenated (CCAT) or VCAT circuits for the CE-100T-8 before
or after provisioning the card’s Ethernet ports and/or packet-over-SDH (POS) ports. See the
Create an Automatically Routed High-Order Circuit” procedure on page 6-55
or the
an Automatically Routed VCAT Circuit” procedure on page 6-97
Step 1
In node view, double-click the CE-100T-8 card graphic to open the card.
Step 2
Click the
Provisioning
>
Ether
Ports
tabs.
Step 3
For each CE-100T-8 port, provision the following parameters:
•
Port Name—If you want to label the port, enter the port name.
Note
Circuit table displays port name of the POS port and not the Ethernet port.
•
Admin State—Choose
Unlocked
to put the port in service.
•
Expected Speed—Choose the expected speed of the device that is or will be attached to the Ethernet
port. If you know the speed, choose
100 Mbps
or
10 Mbps
to match the attached device. If you do
not know the speed, choosing
Auto
enables autonegotiation for the speed of the port, and the
CE-100T-8 port will attempt to negotiate a mutually acceptable speed with the attached device.
•
Expected Duplex—Choose the expected duplex of the device that is or will be attached to the
Ethernet port. If you know the duplex, choose
Full
or
Half
to match the attached device. If you do
not know the duplex, choosing
Auto
enables autonegotiation for the duplex of the port, and the
CE-100T-8 port will attempt to negotiate a mutually acceptable duplex with the attached device.
•
Enable Flow Control—Click this check box to enable flow control on the port (default). If you do
not want to enable flow control, uncheck the box. The CE-100T-8 attempts to negotiate symmetrical
flow control with the attached device.
Purpose
This task provisions CE-100T-8 Ethernet ports to carry traffic.
Tools/Equipment
None
Prerequisite Procedures
DLP-D60 Log into CTC, page 17-49
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...