21-5
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 21 DLPs D400 to D499
DLP- D424 View Alarm or Event History
Step 2
To view node alarm history:
a.
Click the
History > Session
tabs to view the alarms and conditions (events) raised during the current
session.
b.
Click the
History > Shelf
tabs to view the alarm and condition history for the node.
If you check the
Alarms
check box, the node’s alarm history appears. If you check the
Events
check
box, the node’s Not Alarmed and transient event history appears. If you check both check boxes,
you will retrieve node history for alarms and events.
c.
Click
Retrieve
to view all available messages for the History > Shelf tab.
Tip
Double-click an alarm in the alarm table or an event (condition) message in the history table to
display the view that corresponds to the alarm message. For example, double-clicking a card
alarm takes you to card view. In network view, double-clicking a node alarm takes you to node
view.
Step 3
To view network alarm history from node view:
a.
From the View menu, choose
Go to Network View
.
b.
Click the
History
tab.
Alarms and conditions (events) raised during the current session appear.
Step 4
To view card alarm history from node view:
a.
From the View menu, choose
Go to Previous View
.
b.
Double-click a card on the shelf graphic to open the card-level view.
Note
TCC2/TCC2P cards and cross-connect cards do not have a card view.
c.
Click the
History > Session
tabs to view the alarm messages raised during the current session.
d.
Click the
History > Card
tabs and click
Retrieve
to retrieve all available alarm messages for the
card.
If you check the
Alarms
check box, the node’s alarm history appears. If you check the
Events
check
box, the node’s Not Alarmed and transient event history appears. If you check both check boxes, you
will retrieve node history for alarms and events.
Note
The ONS 15454 SDH can store up to 640 critical alarm messages, 640 major alarm
messages, 640 minor alarm messages, and 640 condition messages. When any of these limits
is reached, the ONS 15454 SDH discards the oldest events in that category.
Raised and cleared alarm messages (and events, if selected) appear.
Step 5
Return to your originating procedure (NTP).
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...