21-6
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 21 DLPs D400 to D499
DLP- D425 Create a New or Cloned Alarm Severity Profile
DLP-D425 Create a New or Cloned Alarm Severity Profile
Step 1
Access the alarm profile editor. To do this:
•
From network view, click the
Provisioning > Alarm Profiles
tabs.
shows
the network view.
•
From node view, click the
Provisioning > Alarm Profiles > Alarm Profile Editor
tabs.
•
From card view for an FC_MR-4, E-Series Ethernet, G-Series Ethernet, STM-N, or electrical
(DS3i-N-12, E-1, E1-42, or E-3) card, click the
Provisioning > Alarm Profiles >
Alarm Profile Editor
tabs.
•
From card view for an ML-Series Ethernet (traffic) card, click the
Provisioning >
Ether Alarming > Alarm Profile Editor
tabs or the
Provisioning > POS Alarming >
Alarm Profile Editor
tabs, depending on whether you want to apply the profile to the front physical
ports (“Ether alarming”) or packet over SDH (“POS alarming”). For more information about
ML-Series card ports and service, see the
Ethernet Card Software Feature and Configuration Guide
for the Cisco ONS 15454, Cisco ONS 15454 SDH, and Cisco ONS 15327.
Step 2
If you want to create a new profile based upon the default profile in use, click
New
. Then go to
Step 3
If you want to create a profile using an existing profile located on the node:
a.
Click
Load
and
From Node
in the Load Profile(s) dialog box.
b.
Click the node name you are logged into in the Node Names list.
c.
Click the name of an existing profile in the Profile Names list, such as
Default
.
Step 4
If you want to create a profile using an existing profile located in a file that is stored locally or on a
network drive:
a.
Click
From File
in the Load Profile(s) dialog box.
b.
Click
Browse
.
c.
Navigate to the file location in the
Open
dialog box.
d.
Click
Open
.
Note
All default or user-defined severity settings that are Critical (CR) or Major (MJ) are demoted to
Minor (MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474.
Step 5
Click
OK
.
The alarm severity profile appears in the Alarm Profiles window (
). The alarm profile list
contains a master list of alarms that is used for a mixed node network. Some of these alarms might not
be used in all ONS nodes.
Purpose
This task creates a custom severity profile or clones and modifies the
default severity profile.
Tools/Equipment
None
Prerequisite Procedures
DLP-D60 Log into CTC, page 17-49
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...