15-26
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 15 Maintain the Node
NTP- D346 Import Network Element Defaults
Note
Changes to most node defaults reprovision the node when you click Apply. Changes made to
card settings using the Defaults Editor do not change the settings for cards that are already
installed or slots that are preprovisioned for cards, but rather, change only cards that are installed
or preprovisioned thereafter. To change settings for installed cards or preprovisioned slots, see
Chapter 10, “Change Card Settings.”
Note
Changing some NE defaults can cause CTC disconnection or a reboot of the node in order for
the default to take effect. Before you change a default, view the Side Effects column of the
Defaults editor (right-click a column header and select
Show Column > Side Effects
) and be
prepared for the occurrence of any side effects listed for that default.
Step 7
If you are modifying node-level defaults, a dialog box appears confirming whether you want to apply
defaults for node level attributes that will override current provisioning. Click
Yes
.
Step 8
If you are modifying the IIOP Listener Port setting, a dialog box appears warning you that the node will
reboot and asks if you want to continue. Click
Yes
.
Stop. You have completed this procedure.
NTP-D346 Import Network Element Defaults
Note
For a list of card and node default settings, refer to the “Network Element Defaults” appendix in the
Cisco ONS 15454 SDH Reference Manual
.
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at the node where you want to import NE
defaults.
Step 2
Click the
Provisioning > Defaults
tabs.
Step 3
Click
Import
.
Step 4
If the correct file name and location of the desired file do not appear in the Import Defaults from File
dialog box, click
Browse
and browse to the file you are importing.
Step 5
When the correct file name and location appear in the dialog box, click
OK
.
(The correct file name is
15454SDH-defaults.txt if you are importing the factory defaults.)
Purpose
This procedure imports the NE defaults using the NE Defaults editor. The
defaults can either be imported from the CTC software CD (factory
defaults) or from a customized file exported and saved from a node.
Tools/Equipment
None
Prerequisite Procedures
None
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...