5-40
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 5 Turn Up a Network
NTP- D47 Subtend an MS-SPRing from an SNCP
Step 7
As needed, complete the
“DLP-D81 Provision a Proxy Tunnel” task on page 17-73
Step 8
As needed, complete the
“DLP-D90 Provision a Firewall Tunnel” task on page 17-83
Step 9
Repeat
Step 10
From the View menu, choose
Go To Network View
to view the subtending rings.
Step 11
Complete the
“NTP-D343 SNCP Acceptance Test” procedure on page 5-24
Stop. You have completed this procedure.
NTP-D47 Subtend an MS-SPRing from an SNCP
Step 1
In the SNCP node that will subtend the MS-SPRing, install the two STM-N cards that will serve as the
MS-SPRing trunk (span) cards (in
, Node 3, Slots 5 and 12). See the
STM-N Cards and Connectors” procedure on page 2-7
Step 2
Attach fibers from the cards in
to the MS-SPRing trunk cards on another MS-SPRing node or
nodes. In
, Node 3/Slot 5 connects to Node 2/Slot 12, and Node 3/Slot 12 connects to Node
1/Slot 5. See the
“DLP-D338 Install Fiber-Optic Cables for MS-SPRing Configurations” task on
.
Step 3
Log into the ONS 15454 SDH that will subtend the MS-SPRing (the node in Step 1). See the
Log into CTC” task on page 17-49
. If you are already logged in, continue with Step
Step 4
Create the DCCs on both STM-N trunk cards (east and west) that will carry the MS-SPRing. See the
“DLP-D363 Provision Regenerator-Section DCC Terminations” task on page 20-68
. Alternatively, if
additional bandwidth is needed for CTC management, complete the
Multiplex-Section DCC Terminations” task on page 20-71
Step 5
Create the subtending MS-SPRing:
a.
Complete the
“NTP-D40 Provision MS-SPRing Nodes” procedure on page 5-10
for each node that
will be in the MS-SPRing. If you have already provisioned the MS-SPRing, perform this procedure
for the subtending node only.
b.
Complete the
“NTP-D41 Create the MS-SPRing” procedure on page 5-13
. Include the node in
(the node that will subtend the MS-SPRing) in the MS-SPRing.
Step 6
From the View menu, choose
Go to the Network View
to see the subtending ring.
Stop. You have completed this procedure.
Purpose
This procedure subtends an MS-SPRing from an existing SNCP ring.
Tools/Equipment
One SNCP node must have STM-N cards and fibers to carry the
MS-SPRing.
Prerequisite Procedures
NTP-D44 Provision SNCP Nodes, page 5-22
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...