2-13
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 2 Install Cards and Fiber-Optic Cable
NTP- D286 Install the FC_MR-4 Cards
Warning
Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products.
Statement 291
Warning
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do
not view directly with optical instruments. Viewing the laser output with certain optical instruments
(for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye
hazard.
Statement 1056
Caution
Always use the supplied ESD wristband when working with a powered ONS 15454 SDH. Plug the
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Note
If protective clips are installed on the backplane connectors of the cards, remove the clips before
installing the cards.
Warning
High-performance devices on this card can get hot during operation. To remove the card, hold it by
the faceplate and bottom edge. Allow the card to cool before touching any other part of it or before
placing it in an antistatic bag.
Statement 201
Step 1
If you installed XC-VXL-2.5G cards, review
to determine card/slot compatibility.
If you installed XC-VXL-10G or XC-VXC-10G cards, review
to determine
card/slot compatibility.
Step 2
Open the card latches/ejectors.
Step 3
Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the
receptacle at the back of the slot.
Step 4
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Note
It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
Note
If you install the wrong card in a slot, complete the
“NTP-D227 Remove and Replace a Card”
Step 5
Verify the LED activity:
•
The red FAIL LED turns on for 20 to 30 seconds. The ACT LED is amber for 3 to 5 seconds.
•
The red FAIL LED blinks for up to 2 minutes.
•
The FAIL and ACT LEDs blink once and turn off for 1 to 5 seconds.
•
The ACT LED illuminates green.
Note
If the red FAIL LED does not turn on, check the power.
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...