20-55
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D343 Change SDH Threshold Settings for STM-N Cards
NPJC-PDET
Negative Pointer Justification Count, STS Path Detected. Available for
Line; Near End and Far End.
PPJC-PGEN
Positive Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
NPJC-PGEN
Negative Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
PSC
Protection Switching Count (Line). Available for Line; Near End and Far
End.
PSD
Protection Switch Duration (Line). Available for Line; Near End and Far
End.
PSC-W
Protection Switching Count—Working Line. Available for Line; Near End
and Far End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-W performance monitoring (PM) parameter does not
increment.
PSD-W
Protection Switching Duration—Working Line. Available for Line; Near
End and Far End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-WPM parameter does not increment.
PSC-S
Protection Switching Count—Span. Available for Line; Near End and Far
End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-S PM parameter does not increment.
PSD-S
Protection Switching Duration—Span. Available for Line; Near End and
Far End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-S PM parameter does not increment.
PSC-R
Protection Switching Count—Ring. Available for Line; Near End and Far
End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-R PM parameter does not increment.
PSD-R
Protection Switching Duration—Ring. Available for Line; Near End and
Far End.
Note
MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-R PM parameter does not increment.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 1-day intervals.
Table 20-26
STM-N Threshold Options (continued)
Parameter
Description
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...