7-5
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 7 Manage Circuits
NTP- D78 Create a Monitor Circuit
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
for a node on the network where you want
to delete the circuit. If you are already logged in, continue with Step 2.
Step 2
As needed, complete the
“DLP-D29 Change Tunnel Type” task on page 17-24
Step 3
As needed, complete the
“DLP-D30 Repair an IP Tunnel” task on page 17-25
Step 4
As needed, complete the
“DLP-D31 Delete Overhead Circuits” task on page 17-25
.
Step 5
As needed, complete the
“DLP-D207 Delete a Server Trail” task on page 19-5
.
Stop. You have completed this procedure.
NTP-D78 Create a Monitor Circuit
Note
Monitor circuits cannot be used with EtherSwitch circuits.
Note
For unidirectional circuits, create a drop to the port where the test equipment is attached.
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at a node on the network where you will
create the monitor circuit. If you are already logged in, continue with Step 2.
Step 2
From the View menu, choose
Go to Network View
.
Step 3
Click the
Circuits
tab.
Step 4
Choose the bidirectional (2-way) circuit that you want to monitor and double-click it (or click
Edit)
.
Step 5
Verify that the circuit name is no longer than 44 characters. Monitor circuits append a “_MON” to the
circuit name. If the name is longer than 44 characters, edit the name in the Name field, then click
Apply
.
Step 6
In the Edit Circuit window, click the
Monitors
tab.
The Monitors tab provides ports that you can use to monitor the circuit. The Monitor tab is only available
when the circuit has a DISCOVERED status.
Step 7
In the Monitors tab, choose the monitor source port.
The monitor circuit will show traffic coming into
the node at the port you choose.
Step 8
Click
Create Monitor Circuit
.
Step 9
In the Circuit Destination section of the Circuit Creation wizard, choose the destination node, slot, port,
and if applicable, VC for the monitored circuit.
Purpose
This procedure creates a monitor circuit that monitors traffic on primary,
bidirectional circuits on E1 or STM-1 cards.
Tools/Equipment
None
Prerequisite Procedures
Bidirectional (2-way) circuits must exist on the network. See
“Create Circuits and Low-Order Tunnels”
for circuit creation procedures.
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...