6-80
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D143 Create an E-Series Hub-and-Spoke Ethernet Configuration
NTP-D143 Create an E-Series Hub-and-Spoke Ethernet
Configuration
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at the hub node (the common endpoint). If
you are already logged in, continue with
.
Step 2
If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the
“DLP-D314 Assign a Name to a Port” task on page 20-7
. If you want CTC to assign a name
automatically based on circuit type, node name, and sequence number, continue with
Step 3
Complete the
“DLP-D99 Determine Available VLANs” task on page 17-98
to verify that sufficient
VLAN capacity is available. (You will create a VLAN during each circuit creation task.)
Step 4
Verify that the Ethernet card that will carry the hub-and-spoke circuit is provisioned for Single-card
EtherSwitch Group. See the
“DLP-D246 Provision E-Series Ethernet Card Mode” task on page 19-50
Step 5
Provision and enable the Ethernet ports. See
“DLP-D220 Provision E-Series Ethernet Ports” task on
.
Step 6
Log into the spoke node and repeat Steps
and
for the Ethernet card in the other circuit endpoint. (You
only need to verify that the hub node is provisioned for single-card EtherSwitch once.)
Step 7
Click the
Circuits
tab and click
Create
.
Step 8
In the Circuit Creation dialog box, complete the following fields:
•
Circuit Type—Choose
VC_HO_PATH_CIRCUIT
.
•
Number of Circuits—Leave the default (1) unchanged.
•
Auto-ranged—Unavailable.
Step 9
Click
Next
.
Step 10
Define the circuit attributes:
•
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
•
Size—Choose the circuit size. Valid circuit sizes for a single-card EtherSwitch circuit are
VC4
,
VC4-2c
, and
VC4-4c
.
•
Bidirectional—Leave the default unchanged (checked).
•
Create cross-connects only (TL1-like)—Check this check box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. If you check this box, low-order
tunnels and Ethergroup sources and destinations are unavailable.
Purpose
This procedure creates a hub-and-spoke Ethernet configuration, which is
made up of multiple circuits that share a common endpoint. It does not
apply to E-Series cards in port-mapped mode.
Tools/Equipment
E-Series Ethernet cards (E100T-G or E1000-2-G) must be installed at all
Ethernet circuit endpoint nodes.
Prerequisite Procedures
NTP-D127 Verify Network Turn-Up, page 6-5
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...