6-85
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect
Step 23
Complete the
“DLP-D221 Provision E-Series Ethernet Ports for VLAN Membership” task on
.
Step 24
Complete the
“NTP-D146 Test E-Series Circuits” procedure on page 6-89
Stop. You have completed this procedure.
NTP-D145 Create an E-Series Multicard EtherSwitch Manual
Cross-Connect
Note
In this procedure, cross-connect refers to a circuit connection created within the same node between the
Ethernet card and an STM-N card connected to third-party equipment. You create cross-connects at the
source and destination nodes so an Ethernet circuit can be routed from source to destination across
third-party equipment.
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at a circuit endpoint. If you are already
logged in, continue with
Step 2
If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the
“DLP-D314 Assign a Name to a Port” task on page 20-7
. If you want CTC to assign a name
automatically based on circuit type, node name, and sequence number, continue with
.
Step 3
Complete the
“DLP-D99 Determine Available VLANs” task on page 17-98
to verify that sufficient
VLAN capacity is available. (You will create a VLAN during each circuit creation task.)
Step 4
Verify that the Ethernet card that will carry the circuit is provisioned for Multicard EtherSwitch Group.
See the
“DLP-D246 Provision E-Series Ethernet Card Mode” task on page 19-50
.
Step 5
Provision and enable the Ethernet ports. See
“DLP-D220 Provision E-Series Ethernet Ports” task on
.
Step 6
From the View menu, choose
Go to Network View
.
Step 7
Click the
Circuits
tab and click
Create
.
Step 8
In the Circuit Creation dialog box, complete the following fields:
•
Circuit Type—Choose
VC_HO_PATH_CIRCUIT
.
•
Number of Circuits—Leave the default unchanged (1).
•
Auto-ranged—Unavailable.
Step 9
Click
Next
.
Purpose
This procedure manually creates multicard EtherSwitch cross-connects
between E-Series Ethernet cards and STM-N cards connected to non-ONS
equipment.
Tools/Equipment
E-Series Ethernet cards must be installed at the circuit source node.
Prerequisite Procedures
NTP-D127 Verify Network Turn-Up, page 6-5
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...