20-45
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D340 Change Line and Threshold Settings for the E3-12 Cards
describes the values on the Provisioning > Line Thresholds tab for the E3-12 cards. Only
near-end line threshold options are supported for this card.
Service
State
(Display only) Identifies the
autonomously generated state that gives
the overall condition of the port. Service
states appear in the format: Primary
State-Primary State Qualifier, Secondary
State. For more information about service
states, refer to the “Administrative and
Service States” appendix of the
Cisco ONS 15454 SDH Reference
Manual
.
•
Unlocked-enabled—The port is fully
operational and performing as
provisioned.
•
Unlocked-disabled,automaticInService—
The port is out-of-service, but traffic is
carried. Alarm reporting is suppressed.
The ONS node monitors the ports for an
error-free signal. After an error-free
signal is detected, the port stays in the
Unlocked-disabled,automaticInService
state for the duration of the soak period.
After the soak period ends, the port
service state changes to
Unlocked-enabled.
•
Locked-enabled,disabled—The port is
out-of-service and unable to carry
traffic.
•
Locked-enabled,maintenance—The port
is out-of-service for maintenance.
Alarm reporting is suppressed, but
traffic is carried and loopbacks are
allowed.
AINS Soak
Sets the automatic in-service soak period.
•
Duration of valid input signal, in hh.mm
format, after which the card becomes
Unlocked-enabled automatically
•
0 to 48 hours, 15-minute increments
Table 20-14
Line Options for E3-12 Cards (continued)
Parameter
Description
Options
Table 20-15
Line Threshold Options for E3-12 Cards
Parameter
Description
Port
(Display only) Port number; 1 to 12.
CV
Coding violations.
ES
Errored seconds.
SES
Severely errored seconds.
LOSS
Loss of signal seconds; number of one-second intervals containing one or
more LOS defects.
15 Min radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 15-minute intervals.
1 Day radio button
Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 1-day intervals.
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...