background image

1

Remote Control Switchers

Fig. 2

   ID Code Switch

INSTALLATION INSTRUCTIONS

RT16-10

ADDRESSABLE INFRARED ROUTER

The RT16-10 is a ONE-IN/SIXTEEN-OUT IR switcher which directs an infrared control signal to any one
of 16 output ports, any combination of ports, or all 16 as a group.  You can control large groups of TV
monitors (or any other A/V product) from control locations using Xantech IR Receivers or Smart Pads.  Up
to 16 devices may be addressed with one RT16-10.  Additional RT-10's can be connected for control of
larger numbers of devices, such as TV monitors in a sports bar, by using different IR code groups on each
unit.  The "I" and "G" output ports can drive LED indicators placed at each controlled device location so that
you can see which devices are being addressed at any given time.

ON (1)

OFF (0)

1   2   3   4   5   6

ON

Address Switches

Single/Multiple
Routing Switch
ON (1) - Multiple
OFF (0) - Single

Contoller Select Switch
ON (1) - CTR16
OFF (0) - RC68+

Fig. 1 

  Model RT16-10 Addressable IR Router

1   2   3   4   5   6

ON

Factory Installed Jumper.

DATA IN

DATA OUT

2

O G G I

4

O G G I

6

O G G I

8

O G G I

10

O G G I

12

O G G I

14

O G G I

16

O G G I

1

3

5

7

9

11

13

15

I = INDICATOR,    O = OUTPUT,    G = GROUND,   S = SIGNAL

IR RCVR

INPUT

 +12 G G

S

 S

POWER
12 VOLTS
1 AMP D.C.

ID CODE SWITCH

I G G O

I G G O

I G G O

I G G O

I G G O

I G G O

I G G O

I G G O

RT16 -10

 • 

ADDRESSABLE IR ROUTER

FEATURES AND SPECIFICATIONS

•The RT16-10 requires the XANTECH RC68+ (or RC68) Hand Held Programmer codes, set to a matching

IR Code Group, to address 16 ports individually or in any combination of groups.

• GP-ON (group on) and GP-OFF (group off) codes from the RC68+ select and deselect all 16 ports together

as a group.

• The factory preset IR Code Group is 70.  It can be installer changed by use of the RC68+ Programmer.

• ID CODE SWITCH.  Switches  2 ~ 6 of this 6 position

DIP swtich are reserved for future enhancements.
NOTE:  The unit willnot operate with RC68+ IR control
signals unless switches 2~6 are all set to the OFF
psition.
  Switch 1 selects between single and multiple
routing.  OFF = Single Routing, ON = Multiple Routing.

• The DATA IN and DATA OUT modular jacks allow

future cascading enhancements.

• One IR input on a 4-terminal plug-in connector permits connection of any Xantech IR Receiver, Keypad,

Controller, etc.

• An LED, adjacent to the IR RCVR INPUT, flashes when any IR commands are received (not just those

that are RT16-10 specific).

• 16 IR "O" and "G" emitter outputs and 16 "I" and "G" indicator outputs are located on 16 plug-in connectors.

• The "I" and "G" indicator outputs are current limited to 25 mA, allowing the direct connection of an LED

without the need for a current limiting resistor.

• Power Jack: 2.1mm.  12V DC @ 1 Amp.  Requires one 782-00 Power Supply for each RT16-10.

• Universal mounting fits 19" racks.

• Dimensions:  19" x 3 1/2" x 1 1/4".

• Weight:  1 lb. 3 oz.

Содержание RT1610

Страница 1: ...I G G O I G G O I G G O I G G O RT16 10 ADDRESSABLE IR ROUTER FEATURES AND SPECIFICATIONS The RT16 10 requires the XANTECH RC68 or RC68 Hand Held Programmer codes set to a matching IR Code Group to address 16 ports individually or in any combination of groups GP ON groupon andGP OFF groupoff codesfromtheRC68 selectanddeselectall16portstogether as a group The factory preset IR Code Group is 70 It c...

Страница 2: ...or example pressing button 5 labeled 00 on the button face on the RC68 will cause the RT16 10 to route the IR signal through to the number 5 output GP ON group ON This button labeled 60 on the button face causes the RT16 10 to route IR commands to all 16 outputs at the same time GP OFF group OFF This button labeled 88 on the button face causes the RT16 10 to shut off all or any smaller group of on...

Страница 3: ... of each sequence CAUTION Eachtimeyouadjustswitch1to select the desired Single or Multiple mode you must remove power from the RT16 10 for a few moments for the change to take effect 3 GP ON Group On all 16 as a group In this mode all 16 routes are chosen in stantly with the GP ON command This is useful if you wish to quickly address all groups at the same time All 16 IR routes remain on until the...

Страница 4: ...hannel Up Down 6 Teach the commands into the assigned keys following the instructions that come with the learning device On the URC and the Smart Pad3 all these commands could go into one bank 7 The I and G terminals on each of the output terminal jacks are provided so that LED indicators placed near each TV Monitor if desired will give a visual indication of the currently controlled Monitor Refer...

Страница 5: ... MONITOR 283M TV MONITOR TV MONITOR 15 14 13 12 10 8 6 4 2 11 9 7 5 3 1 782 00 Power Supply 1 2 3 4 5 6 ON Jumper between the G and GS terminals see CAUTION pg 2 Smart Pad Smart Pad DATA IN DATA OUT 2 O G G I 4 O G G I 6 O G G I 8 O G G I 10 O G G I 12 O G G I 14 O G G I 16 O G G I 1 3 5 7 9 11 13 15 I INDICATOR O OUTPUT G GROUND S SIGNAL IR RCVR INPUT POWER 12 VOLTS 1 AMP D C ID CODE SWITCH I G G...

Страница 6: ...ed Side Smart Pad MODEL RT16 10 ADDRESSABLEIRROUTER RF IR RF IR CPL10 RF IR RF IR CPL10 RF IR RF IR CPL10 RF IR RF IR CPL10 RF IR RF IR CPL10 TV Monitor RF IR RF IR CPL10 RF IR RF IR CPL10 RF IR RF IR CPL10 Coaxial Cables IR OUT TV Monitor TV Monitor TV Monitor TV Monitor TV Monitor TV Monitor TV Monitor 782 00 Power Supply 1 2 3 4 5 6 ON Long Coaxial Cables 12VDC 12 VDC GND STATUS IR IN EMITTERS ...

Отзывы: