6-97
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D283 Create an Automatically Routed VCAT Circuit
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at an ONS 15454 SDH on the network
where you will create the overhead circuit. If you are already logged in, continue with Step 2.
Step 2
From the View menu, choose
Go to Network View
.
Step 3
As needed, complete the
“DLP-D361 Create a DCC Tunnel” task on page 20-66
Step 4
As needed, complete the
“DLP-D4 Create an IP-Encapsulated Tunnel” task on page 17-3
.
Step 5
As needed, complete the
“DLP-D83 Provision Orderwire” task on page 17-76
Step 6
As needed, complete the
“DLP-D212 Create a User Data Channel Circuit” task on page 19-9
Stop. You have completed this procedure.
NTP-D283 Create an Automatically Routed VCAT Circuit
Step 1
Complete the
“DLP-D60 Log into CTC” task on page 17-49
at the node where you will create the VCAT
circuit. If you are already logged in, continue with Step 2.
Step 2
Complete the following as necessary (you can provision Ethernet or POS ports before or after the VCAT
circuit is created):
•
To provision Ethernet ports for CE-100T-8 circuits, complete the
Ethernet Ports” task on page 18-30
•
To provision Ethernet ports for CE-1000-4 circuits, complete the
Ethernet Ports” task on page 19-8
•
To provision POS ports for CE-100T-8 or CE-1000-4 circuits, complete the
CE-100T-8 and CE-1000-4 POS Ports” task on page 18-33
.
•
To provision Ethernet ports for ML-Series circuits, complete the
“DLP-D493 Provision the Ethernet
Port of the ML-Series Card” task on page 21-49
•
To provision POS ports for ML-Series circuits, complete the
“DLP-D494 Provision the POS Port of
the ML-Series Card” task on page 21-50
Step 3
From the View menu, choose
Go to Network View
.
Step 4
Click the
Circuits
tab, then click
Create
.
Step 5
In the Circuit Creation dialog box, choose
VC_HO_PATH_VCAT_CIRCUIT
from the Circuit Type
drop-down list.
Step 6
Click
Next
.
Purpose
This procedure creates an automatically routed VCAT circuit. For more
information about VCAT circuits, refer to the “Circuits and Tunnels”
chapter in the
Cisco ONS 15454 SDH Reference Manual
.
Tools/Equipment
ML-Series, CE-100T-8, CE-1000-4, or FC_MR-4 cards must be installed
at the nodes used in the VCAT circuit.
Prerequisite Procedures
NTP-D127 Verify Network Turn-Up, page 6-5
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Provisioning or higher
Содержание ONS 15454 SDH
Страница 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Страница 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Страница 414: ...16 4 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Chapter 16 Power Down the Node NTP D114 Power Down the Node ...
Страница 832: ...A 14 Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...