4-19
Cisco Broadband Cable Command Reference Guide
OL-1581-08
Chapter 4 Commands for the Cisco uBR10012 Router
facility-alarm
The following commands disable major and minor alarms for both the core and intake temperature
thresholds (but critical alarms are still generated):
Router#
configure terminal
Router(config)#
no facility-alarm core-temperature major
Router(config)#
no facility-alarm core-temperature minor
Router(config)#
no facility-alarm intake-temperature major
Router(config)#
no facility-alarm intake-temperature minor
Router(config)#
Related Commands
Command
Description
clear facility-alarm
Clears some or all of the facility alarms on the Cisco uBR10012 router.
show facility-alarm
status
Displays the current temperature thresholds that will trigger a facility
alarm.