Chapter 3 Cisco CMTS Show Commands
show controllers cable
The following is typical output for a downstream on the Cisco uBR-MC28U cable interface line card, or
other cable interface card with integrated upconverter:
ubr7246vxr#
show controllers cable 6/0 downstream
Interface Cable6/0
Hardware is MC28U (F-connector) with Integrated Up-converter
Primary rommon version is: 11.4
Secondary rommon version is: 6553.5
Current rommon is Primary
Late input drops = 0
Output queue: 0/1000/64/0 (size/max total/threshold/drops)
JIB version 372
H/W Spectrum Management Information:
BCM3138 Chip State: 1 1 1 1, Serial Port State 1, Busy Count: 0 25 0 0
Spectrum Management IPC Statistics:
Tx Statistics
Pkts: 48413, Lock Errs: 0, MB not Empty: 0, No Buffs: 0
Rx Statistics
Pkts: 46097, Timeout: 1, Unexpected: 0, No Buffs: 0, Lock Errs: 0
Inuse band lower=0 upper=0 CNR=56
candidate band lower=0 upper=0 Mod=0
Inuse band lower=0 upper=0 CNR=52
candidate band lower=0 upper=0 Mod=0
Inuse band lower=0 upper=0 CNR=55
candidate band lower=0 upper=0 Mod=0
Inuse band lower=23000 upper=26200 CNR=55
candidate band lower=23000 upper=26200 Mod=0
Cable6/0 Upconverter is Enabled Output is Enabled
Model: 74-2094-05 Serial Number: 0WAV06530029 CLEI Code: FFFFFFFFFF
HW Rev: PC2D0108 SW Rev: 010, NVRAM Rev: 006 ECI number FFFFFF
Downstream Frequency 471.0000 MHz
RF Power 54.9 dBmv
Router#
Table 3-44
describes the fields related to the integrated upconverter that are displayed by the
show
controllers cable downstream
command.
The following is sample output from the
show controllers cable upstream
command for a Cisco CMTS
router with a cable interface card located in slot 4, port 0:
CMTS01#
show controllers cable 4/0 upstream 2
Cable4/0 Upstream 2 is administratively down
Frequency 5.008 MHz, Channel Width 0.200 MHz, QPSK Symbol Rate 0.160 Msps
Spectrum Group 4
SNR measurement - 27.2340 dB
Table 3-44 show controllers cable downstream upconverter Field Descriptions
Field
Description
Downstream Frequency
Indicates the center frequency (in MHz) for which the integrated
upconverter has been configured.
IF Power
Indicates the power level (in dBmV) of the signal that the
integrated upconverter is receiving from the cable interface line
card in the Cisco uBR7100 series router.
RF Power
Indicates the power level (in dBmV) of the RF output signal that
the integrated upconverter is transmitting on the DS0 RF port.