background image

44428235 

Assembly instruction

 

 

Valid from 

28.07.2021

 

EPIC

®

 SOLAR 4PLUS 

 

Document: L44428235EN 
Version: 03 

Page 1 of 8 

We reserve all rights according to DIN ISO 16016.

 

EPIC

®

 SOLAR 4PLUS ASSEMBLY INSTRUCTION 

 

Contents 

Contacts ....................................................................................................................................... 2

 

Technical Specifications ............................................................................................................... 2

 

Safety Instructions ........................................................................................................................ 3

 

Necessary Tools ............................................................................................................................ 4

 

Mounting of EPIC

®

 SOLAR 4PLUS ................................................................................................ 5

 

Analysing the cable ....................................................................................................................... 5

 

Preparing the cable ....................................................................................................................... 5

 

Stripping the cable ........................................................................................................................ 5

 

Crimping the contacts .................................................................................................................. 6

 

Mounting ....................................................................................................................................... 7

 

Connecting and Disconnecting ..................................................................................................... 7

 

Laying the cable ............................................................................................................................ 8

 

 

Trademark 

on the Product: 

EPIC

® 

 

Scope of delivery

 

The Connector EPIC

®

 SOLAR 4PLUS is delivered pre-assembled, the necessary contacts are 

included separately. 
EPIC SOLAR 4Plus X Y 

Item number 

Designation  

44428235 

EPIC SOLAR 4PLUS M 

4,0 mm² or 6,0 mm²

 

44428236 

EPIC SOLAR 4PLUS F 

4,0 mm² or 6,0 mm²

 

44428237 

EPIC SOLAR 4PLUS M 

10,0 mm²

 

44428238 

EPIC SOLAR 4PLUS F 

10,0 mm²

 

Symbol 

Signification 

X: 

M (male) or F (female)

 

Y: 

Cross sections 4,0 mm²; 6,0 mm² or 10,0 mm²

 

 
 

Содержание EPIC SOLAR 4Plus M

Страница 1: ...ble 5 Stripping the cable 5 Crimping the contacts 6 Mounting 7 Connecting and Disconnecting 7 Laying the cable 8 Trademark on the Product EPIC Scope of delivery The Connector EPIC SOLAR 4PLUS is deliv...

Страница 2: ...ions According to IEC 62582 2014 Rated Voltage 1 500V DC Rated Current 30A 4 0 mm 30A 6 0 mm 30 A 10 mm Rated impulse withstand voltage 16 kV Rated temperature 40 C 85 C Upper limit of Temperature 105...

Страница 3: ...U 1 0 1 0 kV DC 1 5 kV Max Voltage DC 1 8 kV Conductor Earth System without Earth connection Mated connectors are IP68 protected 1m 10h Continuous ooperation under water e g water on the roof skin of...

Страница 4: ...LAPP Universal Strip Solar Item number 21920120 EPIC SOLAR Mounting Tool is not necessary Two 19 mm open end wrenches are also working Crimping Tool Note To comply the tested quality it s necessary t...

Страница 5: ...SOLAR 4PLUS Female Connector field mountable including Contacts 44428236 EPIC SOLAR 4PLUS F 4 mm 6 mm 4 6 5 2 7 1 8 30 44428238 EPIC SOLAR 4PLUS F 10 mm 10 5 2 7 1 12 30 EPIC SOLAR 4PLUS Male Connect...

Страница 6: ...letely into the crimp area of the contact The cable is pushed forward until the insulation strikes the crimp receptacle of the contact In this way a supernatant of at least 2 mm is ensured Completely...

Страница 7: ...Turn cap nut hand tight 4 5 Nm finished Spanner size 19 EPIC SOLAR 4PLUS F Connecting and Disconnecting Before plugging in check the plugging area for possible soiling and clean it if necessary Especi...

Страница 8: ...es must be firmly laid in the photovoltaic system securely fastened and the minimum bending radius must not be undercut The cable must be led straight out of the connector at least L 50 mm The bending...

Отзывы: