Necessary Tools 

 

Cable shears for cutting the PV-cables: 

 

 

 

LAPP Cable shear KS20, Item number 62120523 
 
 

Stripping Tool to strip the PV-Cable 

 

 

 

LAPP Universal Strip Solar, Item number 21920120 
 

EPIC

®

 SOLAR Mounting Tool is not necessary: 

Two 19 mm open-end wrenches are also working. 
 

Crimping Tool 
Note:  

To comply the tested quality, it`s necessary to use only the indicated tools. 

 

 

 

 

   

Crimptool CSC Parts 

 

Crimptool CSC mounted 

 
Crimptool (11147000) with crimp inserts (e.g. 44428266) and locator (44428244)  
to crimp the EPIC

®

 SOLAR contacts: 

 
Alternating the CSC insert can be used with the Crimping Tool. This insert has the function 

c

ut, 

s

tripping and 

c

rimping. 

Содержание EPIC SOLAR 4Plus M

Страница 1: ...ble 5 Stripping the cable 5 Crimping the contacts 6 Mounting 7 Connecting and Disconnecting 7 Laying the cable 8 Trademark on the Product EPIC Scope of delivery The Connector EPIC SOLAR 4PLUS is deliv...

Страница 2: ...ions According to IEC 62582 2014 Rated Voltage 1 500V DC Rated Current 30A 4 0 mm 30A 6 0 mm 30 A 10 mm Rated impulse withstand voltage 16 kV Rated temperature 40 C 85 C Upper limit of Temperature 105...

Страница 3: ...U 1 0 1 0 kV DC 1 5 kV Max Voltage DC 1 8 kV Conductor Earth System without Earth connection Mated connectors are IP68 protected 1m 10h Continuous ooperation under water e g water on the roof skin of...

Страница 4: ...LAPP Universal Strip Solar Item number 21920120 EPIC SOLAR Mounting Tool is not necessary Two 19 mm open end wrenches are also working Crimping Tool Note To comply the tested quality it s necessary t...

Страница 5: ...SOLAR 4PLUS Female Connector field mountable including Contacts 44428236 EPIC SOLAR 4PLUS F 4 mm 6 mm 4 6 5 2 7 1 8 30 44428238 EPIC SOLAR 4PLUS F 10 mm 10 5 2 7 1 12 30 EPIC SOLAR 4PLUS Male Connect...

Страница 6: ...letely into the crimp area of the contact The cable is pushed forward until the insulation strikes the crimp receptacle of the contact In this way a supernatant of at least 2 mm is ensured Completely...

Страница 7: ...Turn cap nut hand tight 4 5 Nm finished Spanner size 19 EPIC SOLAR 4PLUS F Connecting and Disconnecting Before plugging in check the plugging area for possible soiling and clean it if necessary Especi...

Страница 8: ...es must be firmly laid in the photovoltaic system securely fastened and the minimum bending radius must not be undercut The cable must be led straight out of the connector at least L 50 mm The bending...

Отзывы: