![Cisco 350XG series Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/cisco/350xg-series/350xg-series_administration-manual_67491046.webp)
Status and Statistics
Health
Cisco 350XG & 550XG Series 10G Stackable Managed Switches
42
4
To view the device health parameters, click
Status and Statistics
>
Health
.
The Health page displays the following fields:
•
Unit No.
—Displays the unit number.
•
Fan Status
—The following values are possible:
-
OK
—Fan is operating normally.
-
Failure
—Fan is not operating correctly.
-
N/A
—Fan ID is not applicable for the specific model.
•
Redundant Fan Status
—(Only supported on 550 family) The following
values are possible:
-
Ready
—Redundant fan is operational but not required.
-
Active
—One of the main fans is not working and this fan is replacing it.
-
Failure
—Redundant fan is not operating correctly.
•
Temperature
—The options are:
-
OK
—The temperature is below the warning threshold.
-
Warning
—The temperature is between the warning threshold to the
critical threshold.
-
Critical
—Temperature is above the critical threshold.
-
N/A
—Not relevant.
•
Power Supply Status
—The options are:
-
Main
—Displays one of the following:
Active—Power supply is being used.
Failure—Main power has failed.