Displays:
•
Engine Temperature
•
Oil Pressure
•
Fuel Level
•
Engine Speed
•
AC Metering
•
Battery Voltage
•
Real Time Clock
•
Engine Hours
•
Time to Maintenance
•
J1939 DTCs + Custom Text
•
Custom Senders
•
Warnings and Failures
1.1
Specifications
The TOUGH Series controllers were rigorously tested to ensure durability, reliability and functionality. The
following specifications are a brief summary of the standards to which the controller has been tested. For
complete details on the testing performed, please contact Cattron at
Testing Specifications
Specification
Rating
Electrical Transients
SAE1113-11
Thermal Shock and Cycling
SAE1455
Vibration Profiles
SAE1455
Electric Static Discharge
SAE1113-13: SAE1113-13:
+/-8 kV Direct Discharge
+/-15 kV Air Gap Discharge
UL
UL 6200 recognized component. Contact Cattron at
for UL conditions of acceptability.
Physical Specifications
Specification
Rating
Operating Temperature
-40 to +158 °F (-40 to +70 °C)
LCD Viewing Temperature
-4 to +158 °F (-20 to +70 °C)
(Optional heater available, contact Cattron at
Содержание DYNAGEN TOUGH Series TE410
Страница 1: ...TOUGH SeriesTM TE410 User Manual ...
Страница 14: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 14 9M02 9249 A001 EN Revision A 2 3 Wiring Harness ...
Страница 15: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 15 9M02 9249 A001 EN Revision A 2 4 Typical Wiring Diagram ...
Страница 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Страница 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Страница 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...