Name
Range
Description
Wind Machine >
Thresholds > High
Fail
0.1 ~ 510 in 0.1
increments
Controller shuts down on Transducer (Aux Sensor 5)
“High
Failure
” if the transducer value rises above this set point.
The Throttling sub menu more or less replicates settings in the Sensors > Engine Speed menu, the Other Config
> Pump System menu, the Timers > Engine Logic menu, and others.
Name
Range
Description
Throttling > RPM
Settings > Idle
RPM
300 ~ 2000 RPM
in 1 RPM increments
The J1939 TSC1 speed sent to the ECM when the
controller is in Idle Mode.
Throttling > RPM
Settings > Interm
RPM
500 ~ 4000 RPM
in 1 RPM increments
The J1939 TSC1 speed sent to the ECM when the
controller is in Intermediate Mode (between Idle and
rated/goal speed).
Throttling > RPM
Settings > Rated
RPM
500 ~ 4000 RPM
in 1 RPM increments
The rated running RPM of the engine. The RPM that
corresponds to 50/60 Hz or to the tooth count.
Throttling > RPM
Settings > Goal
RPM
500 ~ 4000 RPM
in 1 RPM increments
The J1939 TSC1 speed sent to the ECM when the
controller is in normal Running Mode.
Throttling > Dwell
Times > Warm-up
Disabled
5 ~ 600 s
in 5 s increments
The time to spend in warm-up. The engine is idled if idle is
enabled.
Throttling > Dwell
Times > Interm
1 ~ 300 s
in 1 s increments
The time to spend at the intermediate speed.
Throttling > Dwell
Times > Cooldown
Disabled
5 ~ 6000 s
in 5 s increments
The time to spend at cooldown if cooldown is enabled. The
engine is idled if cooldown idle is enabled under Timers >
Engine Logic.
Throttling > Ramp
Times > Dwell 1
1 ~ 300 s
in 1 s increments
The time to spend ramping between idle and intermediate
speeds.
Throttling > Ramp
Times > Dwell 2
1 ~ 300 s
in 1 s increments
The time to spend ramping between intermediate and goal
speeds.
Throttling > Ramp
Times > Dwell 3
1 ~ 300 s
in 1 s increments
The time to speed ramping down from the goal speed to
the idle speed.
Throttling > Ramp
Times > TSC1
RPM/s
Disabled
10 ~ 300 RPM/s
in 10 RPM/s increments
A global setpoint. This limits the maximum rate of change
of the TSC1 speed command. This overrides everything
else including the dwell times.
Throttling > Bump
Speed
0 ~ 500 RPM
in 1 RPM increments
The amount to increase the speed (TSC1) when a user
presses the speed increment / speed decrement buttons.
Содержание DYNAGEN TOUGH Series TE410
Страница 1: ...TOUGH SeriesTM TE410 User Manual ...
Страница 14: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 14 9M02 9249 A001 EN Revision A 2 3 Wiring Harness ...
Страница 15: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 15 9M02 9249 A001 EN Revision A 2 4 Typical Wiring Diagram ...
Страница 22: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 22 9M02 9249 A001 EN Revision A CT Wiring ...
Страница 24: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 24 9M02 9249 A001 EN Revision A ...
Страница 28: ...DynaGenTM TOUGH SeriesTM TE410 EN User Manual 28 9M02 9249 A001 EN Revision A ...