Chapter 12
12-7
Moreover, when it fails in the event waiting in the device and either of a Jam notification, an Alarm notification, and a Service call notification or an Alert notifi-
cation is specified, following string is displayed.
"Event Registration is Failed."
In other cases error information is displayed in the form of the following.
"[*] [Error string]: [Method name] [Server side detailed error]"
The enclosed character string by [] is replaced as follows.
[*]:
*(asterisk) is added to the head of the string only at the communication test.
[Error string]:
As for number 1 and 2 of the following Error string lists, only the Error string is displayed. Besides, it is displayed as "[*] [Error string]: [Method name]
[Server side detailed error]". ([Server side detailed error] might not go out.)
Error string
Cause
Counter Measure
1
SUSPEND: Communication
test is not performed
The e-RDS is started (the device is rebooted) when e-RDS is ON
and communication test isn't done.
Complete the communication test.
2
Event Registration is Failed.
The device failed event processing.
Turn OFF/ON of the device main switch. Or, replace the
system software of the device (upgrade).
3
URL Scheme error (not https) The header of registered URL of UGW is not https.
Change the header on URL of UGW to https
4
Server connection error
Communication failure of TCP/IP occurred.
Or IP address of the device isn't set.
Check the network connection.
5
URL server specified is illegal Illegal URL (other than UGW) is specified.
Correct URL.
6
Proxy connection error
The e-RDS cannot connect it with the proxy server.
Check and correct the proxy server address etc.
7
Proxy authentication error
The e-RDS fails the authentication to proxy.
Check and correct username and password to log in proxy.
8
Server certificate error
- The certificate is not installed in The device.
- The certificate that The user is using is not registered in The
device or The server.
Register the root certificate in the device or register the
VeriSign certificate in the server.
9
Server certificate expired
- Expired certificate is registered in the device or the server.
- The date of the device is outside the time limit of the certificate.
- Register the root certificate in expiration date in the
device or register the VeriSign certificate in the server.
- Set an accurate date to the device.
10
Unknown error
Other communication error occurs.
After waiting for a while, try again.
11
Server response error (NULL) UGW returns the error but communication to UGW is succeeded.
If (NULL) is displayed after the message, the error occurs in the
HTTPS communication.
After waiting for a while, try again.
12
Server response error
(Hexadecimal)
UGW returns the error but communication to UGW is succeeded.
(Hexadecimal) displayed after the message is error code that
UGW returns.
[server side detailed error] is added at the end of error
information only at this error.
After waiting for a while, try again.
13
Device internal error
Device internal error such as the memory cannot be taken occurs. Turn OFF/ON of the device main switch. Or, replace the
system software of the device (upgrade).
14
Server schedule is invalid
Illegal schedule transmission information is set in UGW. (Ex:
Every 30 minutes were set to UGW but the right interval in e-
RDS is 1 hour.)
Correct the schedule transmission information setting in
UGW. (Ex: every 1 hour)
15
Server response time out
There was no reply from UGW in predetermined time.
(The congestion of the network etc.)
It is the timeout at HTTPS level.
After waiting for a while, try again.
Содержание iR7086
Страница 1: ...Sep 7 2007 Service Manual iR7105 7095 7086 Series...
Страница 2: ......
Страница 6: ......
Страница 26: ...Contents...
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 30: ......
Страница 32: ...Chapter 1 1 2 Not all products are necessarily available in all sales areas...
Страница 55: ...Chapter 2 Installation...
Страница 56: ......
Страница 150: ......
Страница 151: ...Chapter 3 Basic Operation...
Страница 152: ......
Страница 154: ......
Страница 159: ...Chapter 4 Main Controller...
Страница 160: ......
Страница 162: ......
Страница 183: ...Chapter 5 Original Exposure System...
Страница 184: ......
Страница 228: ......
Страница 229: ...Chapter 6 Laser Exposure...
Страница 230: ......
Страница 232: ......
Страница 238: ...Chapter 6 6 6 F 6 7 1 Laser light 2 Laser shutter 1 2 1 2 2 1...
Страница 240: ......
Страница 241: ...Chapter 7 Image Formation...
Страница 242: ......
Страница 246: ......
Страница 294: ......
Страница 295: ...Chapter 8 Pickup Feeding System...
Страница 296: ......
Страница 300: ......
Страница 353: ...Chapter 9 Fixing System...
Страница 354: ......
Страница 378: ......
Страница 379: ...Chapter 10 External and Controls...
Страница 380: ......
Страница 384: ......
Страница 394: ...Chapter 10 10 10 F 10 7...
Страница 417: ...Chapter 11 MEAP...
Страница 418: ......
Страница 420: ......
Страница 466: ......
Страница 467: ...Chapter 12 RDS...
Страница 468: ......
Страница 470: ......
Страница 479: ...Chapter 13 Maintenance and Inspection...
Страница 480: ......
Страница 482: ......
Страница 496: ......
Страница 497: ...Chapter 14 Standards and Adjustments...
Страница 498: ......
Страница 526: ......
Страница 527: ...Chapter 15 Correcting Faulty Images...
Страница 528: ......
Страница 530: ......
Страница 560: ......
Страница 561: ...Chapter 16 Self Diagnosis...
Страница 562: ......
Страница 564: ......
Страница 584: ......
Страница 585: ...Chapter 17 Service Mode...
Страница 586: ......
Страница 588: ...Contents 17 8 1 1 COPIER Items 17 94...
Страница 688: ......
Страница 689: ...Chapter 18 Upgrading...
Страница 690: ......
Страница 692: ......
Страница 696: ...Chapter 18 18 4...
Страница 713: ...Chapter 18 18 22 formatting and download the system software once again...
Страница 726: ...Chapter 19 Service Tools...
Страница 727: ......
Страница 728: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 729: ......
Страница 733: ......
Страница 734: ...Sep 7 2007...
Страница 735: ......