Chapter 12
12-1
12.1 RDS
12.1.1 Application operation mode
0011-6831
iR7105 / iR7095 / iR7086 / iR7095P
Serviceman selects the operation mode of OFF/ON by the setting in e-RDS setting screen of the service mode. (Menu Screen: E-RDS)
- OFF (default): e-RDS doesn't operate.
- ON: e-RDS operates every function.
12.1.2 Service Center URL and Port Specification
0011-6832
iR7105 / iR7095 / iR7086 / iR7095P
The URL and the port number of the equipment information destination can be specified as follows.
- Default (specified beforehand)
- Specified by the service mode. (Menu Screen: RGW-ADR, RGW-PORT)
12.1.3 Communication test
0011-6833
iR7105 / iR7095 / iR7086 / iR7095P
Serviceman can distinguish the communication status with the UGW by executing the communication test in the service mode (Menu Screen: COM-TEST), and
referring to the communication log
Error information is displayed in the latest communication log at communication error.
12.1.4 Communication log
0011-6834
iR7105 / iR7095 / iR7086 / iR7095P
The list of the log of the communication error (proxy server error etc.)(For 30) can be displayed in display panel in the service mode. (Menu Screen: COM-LOG)
12.1.5 Detailed Communication log
0011-6835
iR7105 / iR7095 / iR7086 / iR7095P
Detailed information of the error in the communication log can be displayed in display panel. (Log List Screen: Each error)
12.1.6 SOAP communication function
0011-6836
iR7105 / iR7095 / iR7086 / iR7095P
The following processing is achieved by the SOAP communication (SSL client communication).
e-RDS does the host authentication by using the CA*1 certificate of the VeriSign Co..
When the host certificate or the CA certificate is expired, e-RDS doesn't connect to UGW.
*1: CA: Certificate Authority: Organization that issues electronic certificate used by electronic commerce etc
(1) Communication test:
- Do the communication test
(2) Regularly collect the following data, and transmit it.
- Copy Counter
- Service mode counter
- Parts counter
- Mode Counter
- ROM version
- Scheduling information
- Application log
(3) When jam or alarm/service call error is detected from the device, e-RDS transmits to UGW.
- Transmission of alert code(Counter information is transmitted at the same time. )
When the state of the device changes, e-RDS sends the alert code list.
The main alert codes used are Toner LOW/OUT, Jam, and Door open.
When recovering from an error, e-RDS transmits data that shows the recovering from an error again.
- Transmission of Jam log (Counter information is transmitted at the same time.)
- Transmission of Alarm log (Counter information is transmitted at the same time.)
- Transmission of Service Call (Error code) log (Counter information is transmitted at the same time.)
(4) Change of the device scheduling information
- Scheduling information can be changed by the instruction from UGW.
Содержание iR7086
Страница 1: ...Sep 7 2007 Service Manual iR7105 7095 7086 Series...
Страница 2: ......
Страница 6: ......
Страница 26: ...Contents...
Страница 27: ...Chapter 1 Introduction...
Страница 28: ......
Страница 30: ......
Страница 32: ...Chapter 1 1 2 Not all products are necessarily available in all sales areas...
Страница 55: ...Chapter 2 Installation...
Страница 56: ......
Страница 150: ......
Страница 151: ...Chapter 3 Basic Operation...
Страница 152: ......
Страница 154: ......
Страница 159: ...Chapter 4 Main Controller...
Страница 160: ......
Страница 162: ......
Страница 183: ...Chapter 5 Original Exposure System...
Страница 184: ......
Страница 228: ......
Страница 229: ...Chapter 6 Laser Exposure...
Страница 230: ......
Страница 232: ......
Страница 238: ...Chapter 6 6 6 F 6 7 1 Laser light 2 Laser shutter 1 2 1 2 2 1...
Страница 240: ......
Страница 241: ...Chapter 7 Image Formation...
Страница 242: ......
Страница 246: ......
Страница 294: ......
Страница 295: ...Chapter 8 Pickup Feeding System...
Страница 296: ......
Страница 300: ......
Страница 353: ...Chapter 9 Fixing System...
Страница 354: ......
Страница 378: ......
Страница 379: ...Chapter 10 External and Controls...
Страница 380: ......
Страница 384: ......
Страница 394: ...Chapter 10 10 10 F 10 7...
Страница 417: ...Chapter 11 MEAP...
Страница 418: ......
Страница 420: ......
Страница 466: ......
Страница 467: ...Chapter 12 RDS...
Страница 468: ......
Страница 470: ......
Страница 479: ...Chapter 13 Maintenance and Inspection...
Страница 480: ......
Страница 482: ......
Страница 496: ......
Страница 497: ...Chapter 14 Standards and Adjustments...
Страница 498: ......
Страница 526: ......
Страница 527: ...Chapter 15 Correcting Faulty Images...
Страница 528: ......
Страница 530: ......
Страница 560: ......
Страница 561: ...Chapter 16 Self Diagnosis...
Страница 562: ......
Страница 564: ......
Страница 584: ......
Страница 585: ...Chapter 17 Service Mode...
Страница 586: ......
Страница 588: ...Contents 17 8 1 1 COPIER Items 17 94...
Страница 688: ......
Страница 689: ...Chapter 18 Upgrading...
Страница 690: ......
Страница 692: ......
Страница 696: ...Chapter 18 18 4...
Страница 713: ...Chapter 18 18 22 formatting and download the system software once again...
Страница 726: ...Chapter 19 Service Tools...
Страница 727: ......
Страница 728: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2...
Страница 729: ......
Страница 733: ......
Страница 734: ...Sep 7 2007...
Страница 735: ......