8
8
8-207
8-207
Service Mode > COPIER > OPTION > USER
Service Mode > COPIER > OPTION > USER
■
USER
COPIER > OPTION > USER
COPY-LIM
Setting of upper limit for copy
Lv.1 Details
To set the upper limit value for copy.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 9999
Default value
999
SLEEP
ON/OFF of auto sleep function
Lv.1 Details
To set ON/OFF of auto sleep function.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
SIZE-DET
ON/OFF of original size detect function
Lv.2 Details
To set ON/OFF of original size detection function.
Use case
Upon user’s request (glare of the Scan Lamp, etc)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
COUNTER1
Display of software counter 1
Lv.1 Details
To display counter type for software counter 1 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Display only. No change is available.
Display/adj/set range
0 to 999
0: No registration
Default value
The value differs according to the location.
COUNTER2
Setting of software counter 2
Lv.1 Details
To set counter type for software counter 2 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
The value differs according to the location.
COPIER > OPTION > USER
COUNTER3
Setting of software counter 3
Lv.1 Details
To set counter type for software counter 3 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
The value differs according to the location.
COUNTER4
Setting of software counter 4
Lv.1 Details
To set counter type for software counter 4 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
The value differs according to the location.
COUNTER5
Setting of software counter 5
Lv.1 Details
To set counter type for software counter 5 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
0
COUNTER6
Setting of software counter 6
Lv.1 Details
To set counter type for software counter 6 on the Counter Check
screen.
Use case
Upon user/dealer’s request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
0
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Страница 701: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...