8
8
8-123
8-123
Service Mode > COPIER > ADJUST > HV-TR
Service Mode > COPIER > ADJUST > HV-TR
COPIER > ADJUST > HV-TR
2TR-R23
Sec trn ATVC ppr allotV:rcycl 2nd,H-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of recycled
paper in secondary transfer ATVC control at high humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 2TR-N23
2TR-HN1
Sec trn ATVC ppr allot V:pln2 1st,L-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of plain paper 2
in secondary transfer ATVC control at low humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 2TR-N1
COPIER > ADJUST > HV-TR
2TR-HN12
Sec trn ATVC ppr allot V:pln2 1st,N-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of plain paper 2
in secondary transfer ATVC control at normal humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 2TR-N12
2TR-HN22
Sec trn ATVC ppr allot V:pln2 2nd,N-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 2nd side of plain paper 2
in secondary transfer ATVC control at normal humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
When white dots occur on an image, the image failure can be
alleviated by adjusting the value in the -100 to -10 (-3000 to -300V)
range in increments of 10 (30V). However, if the value is too small,
transfer failure occurs.
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 2TR-N22
2TR-HN13
Sec trn ATVC ppr allot V:pln2 1st,H-hmdy
Lv.1 Details
To adjust the paper allotted voltage for the 1st side of plain paper 2
in secondary transfer ATVC control at high humidity.
When transfer failure occurs on an image, adjust the value in the -30
to 30 (-900 to 900V) range in increments of 10 (30V).
Use case
When adjusting the secondary transfer bias according to conditions
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Display/adj/set range
-128 to 127
Unit
V
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 2TR-N13
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...