2
2
2-89
2-89
Technology■>■Fixing■System■>■Controls■>■Protection■features
Technology■>■Fixing■System■>■Controls■>■Protection■features
■
■
Film■unit■engagement■/■disengagement■control
To■prevent■deformation■of■the■fixing■film■/■pressure■roller■caused■by■heat■and■pressure■when■
the■drive■of■pressure■roller■is■stopped,■and■also■to■improve■jam■recovering■performance,■the■
film■unit■is■disengaged■from■the■pressure■roller■under■the■following■conditions:
Disengaged
Pressure roller
Pressure roller
Film unit
Fixing Motor
Fixing pressure sensor (PS30)
Pressure
plate
Pressure
plate
Film unit
Sensor flag
Sensor flag
Cam
Cam
Fixing pressure sensor (PS30)
Engaged
M21
Fixing Motor
M21
Execution■conditions■/■timing
Execution■conditions■/■timing
•■ The■film■unit■is■disengaged■when■the■power■is■
turned■ON
•■ When■the■power■is■turned■OFF
•■ At■jam■detection■when■the■power■is■turned■ON
•■ At■recovery■from■sleep■mode
•■ When■the■mode■is■shifted■to■sleep■mode■(when■
the■power■switch■on■the■control■panel■is■OFF,■
when■the■specified■period■of■time■has■passed■
since■the■mode■has■shifted■to■sleep■mode)
•■ At■recovery■from■jam■removal
•■ When■the■front■cover/right■cover■is■closed.
•■ When■a■jam■occurs
•■ When■an■error■occurs
Related■Error■Codes
E009■(Error■in■engagement/disengagement■of■film■unit)
•■ 0000■■Error■in■engagement
•■ 0001■■Error■in■disengagement
•■ 0002■■Error■in■engagement■(it■is■highly■possible■that■grease■is■scattered■on■the■surface■of■the■
cam.)
F-2-124
■
■
Protection■features
Code
Description
Error
Clear
E001 Detection■of■abnormal■high■temperature
0000 When■main■thermistor■1/2■detects■255■deg■C■or■more■for■0.2■sec.
Clear
0001 When■sub■thermistor■1/2■detects■275■deg■C■or■more■for■0.2■sec
Clear
0003 When■the■thermistor■detects■temperature■beyond■the■upper■value:
Main■thermistor■2■=■265■deg■C
Main■thermistor■1■=■264■deg■C
Sub■thermistor■1■=■280■deg■C
Sub■thermistor■2■=■280■deg■C
Clear
E003 Detection■of■low■temperature■
0000 When■main■thermistor■1/sub■thermistor■1/sub■thermistor2■detects■21■
to■50■deg■C■for■3■sec.
Clear
0001 When■main■thermistor■1■detects■“(target■temperature■–■70■deg■C)”■or■
less■for■5■sec.
Clear
0002 When■the■thermistor■detects■disconnection■(any■thermistor■detects■20■
deg■C■or■less■for■3■sec)
Clear
0003 When■the■control■fails■to■be■completed■60■sec■after■the■start■of■warm-
up■rotation.
Clear
E004 Detection■of■abnormal■fixing■heater■drive■circuit
0000 When■disconnection■of■the■thermistor■is■detected.
Unnecessary
E808 Detection■of■abnormal■fixing■drive■circuit/power■supply
0000 Zero-cross■error■(faulty■low■voltage■circuit)
Unnecessary
T-2-53
Содержание IMAGERUNNER ADVANCE C5030
Страница 17: ...1 1 Product Overvew Product Overvew Product Lineup Feature Specification Name of Parts Operation ...
Страница 259: ...3 3 Periodical Service Periodical Service Consumable Parts Replacement Parts and Cleaning Parts ...
Страница 450: ...5 5 Adjustment Adjustment Main Controller Image Formation System Pickup Feed System ...
Страница 575: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...